General Information | |
Extended Product Type: | AF80N3-30-11-12 |
Product ID: | 1SBL397001N1211 |
EAN: | 3471523016682 |
Catalog Description: | AF80N3-30-11-12 48-130V50/60HZ-DC Contactor |
Long Description: | The AF80N3-30-11-12 is a 3 pole - 600 V UL, NEMA size N3 contactor with pre-mounted auxiliary contacts and Screw, switching power circuits up to 90 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. |
| |
Standards: | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
Product Name: | Block Contactor |
Rated Operational Voltage: | Auxiliary Circuit 690 V |
Main Circuit 1000 V | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Rated Control Circuit Voltage (Uc): | 50 Hz 48 ... 130 V |
50 Hz / 60 Hz 48 ... 130 V | |
60 Hz 48 ... 130 V | |
DC Operation 48 ... 130 V | |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(400 / 440 V) 3 A | |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A | |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | |
for 0.1 s 140 A | |
for 1 s 100 A | |
Rated Frequency (f): | Auxiliary Circuit 50 / 60 Hz |
Main Circuit 50 / 60 Hz | |
Power Loss: | at Rated Operating Conditions AC-1 per Pole 7.6 W |
at Rated Operating Conditions AC-3 per Pole 3 W | |
Number of Main Contacts NC: | 0 |
Number of Main Contacts NO: | 3 |
Number of Auxiliary Contacts NC: | 1 |
Number of Auxiliary Contacts NO: | 1 |
Low Coil Consumption: | No |
Tightening Torque: | Auxiliary Circuit 1.2 N·m |
Control Circuit 1.2 N·m | |
Main Circuit 6 N·m | |
Mounted Auxiliary Contacts: | 1 NO, 1 NC |
Mounting Position: | Max. N.C. built-in and add-on N.C. auxiliary contacts: see accessory fitting details for a 3-pole contactor AF40 ... AF96 |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 6 ... 50 mm² |
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | |
Rigid 1x 6 ... 70 mm² | |
Rigid 2x 6 ... 50 mm² | |
Wire Stripping Length: | Auxiliary Circuit 10 mm |
Control Circuit 10 mm | |
Main Circuit 17 mm | |
Terminal Type: | Screw Terminals |
| |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C |
Close to Contactor without Thermal O/L Relay -40 ... +70 °C | |
Close to Contactor for Storage -60 ... +80 °C | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5 ... 300 Hz 3 g closed position / 3 g open position |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: A 25 K40 |
Closed, Shock Direction: B1 25 K40 | |
Closed, Shock Direction: B2 15 K40 | |
Closed, Shock Direction: C1 25 K40 | |
Closed, Shock Direction: C2 25 K40 | |
Open, Shock Direction: A 25 K40 | |
Open, Shock Direction: B1 5 K40 | |
Open, Shock Direction: B2 15 K40 | |
Open, Shock Direction: C1 25 K40 | |
Open, Shock Direction: C2 25 K40 | |
RoHS Status: | Following EU Directive 2011/65/EU |
Technical UL/CSA | |
General Use Rating UL/CSA: | (600 V AC) 105 A |
Horsepower Rating UL/CSA: | (120 V AC) Single Phase 7-1/2 hp |
(200 ... 208 V AC) Three Phase 25 hp | |
(220 ... 240 V AC) Three Phase 30 hp | |
(240 V AC) Single Phase 15 hp | |
(440 ... 480 V AC) Three Phase 60 hp | |
(550 ... 600 V AC) Three Phase 75 hp | |
Tightening Torque UL/CSA: | Auxiliary Circuit 11 IA |
Control Circuit 11 IA | |
Main Circuit 53 IA | |
| |
Product Net Width: | 82 mm |
Product Net Height: | 125.5 mm |
Product Net Depth / Length: | 116 mm |
Product Net Weight: | 1.26 kg |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 150 mm |
Package Level 1 Height: | 103 mm |
Package Level 1 Depth / Length: | 150 mm |
Package Level 1 Gross Weight: | 1.38 kg |
Package Level 1 EAN: | 3471523016682 |
Package Level 3 Units: | 192 piece |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Country of Origin: | United States (US) |
Selling Unit of Measure: | piece |
| |
CB Certificate: | CB_SE-96557M2 |
cUL Certificate: | UL_20180227_E312527_7_1 |
Declaration of Conformity - CE: | 1SBD250027U1000 |
Instructions and Manuals: | 1SBC101036M6801 |
RoHS Information: | 1SBD250027U1000 |
UL Certificate: | UL_20140305-E312527_7_1 |
UL Listing Card: | UL_E312527 |
Popular Downloads | |
Instructions and Manuals: | 1SBC101036M6801 |
Mounting Positions: | 1SBC500297F0000 |
UL Listing Card: | UL_E312527 |
EPLAN Graphical Macro: | 9AKK106930A0723 |
EPLAN Macro: | 9AKK106930A0722 |
| |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
ETIM 8: | EC000066 - Power contactor, AC switching |
WEEE Category: | Product Not in WEEE Scope |
CN8: | 8536 49 00 |
UNSPSC: | 39121529 |
eClass: | V11.0 : 27371003 |