Артикул: AF40-22-00-11
Артикул: AF40-22-00-11
AF40-22-00-11 24-60V50/60HZ 20-60VDC Contactor
Мы подберем для вас подходящий продукт
Срочная доставка
Параллельный импорт
Конфигурация
General Information | |
Extended Product Type: | AF40-22-00-11 |
Product ID: | 1SBL347501R1100 |
EAN: | 3471523133815 |
Catalog Description: | AF40-22-00-11 24-60V50/60HZ 20-60VDC Contactor |
Long Description: | The AF40-22-00-11 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 18.5 kW / 400 V AC (AC-3) and switching power circuits up to 70 A (AC-1) or 60 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Instructions and Manuals: | 1SBC101047M6801 |
| |
Product Net Width: | 70 mm |
Product Net Depth / Length: | 113.5 mm |
Product Net Height: | 125.5 mm |
Product Net Weight: | 1.21 kg |
| |
Number of Main Contacts NO: | 2 |
Number of Main Contacts NC: | 2 |
Number of Auxiliary Contacts NO: | 0 |
Number of Auxiliary Contacts NC: | 0 |
Rated Operational Voltage: | Main Circuit 690 V |
Rated Frequency (f): | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 70 |
(690 V) 60 °C 60 A | |
(690 V) 70 °C 50 | |
Rated Operational Current AC-3 (Ie): | (415 V) 60 °C 40 A |
(440 V) 60 °C 40 A | |
(500 V) 60 °C 35 A | |
(690 V) 60 °C 25 A | |
(380 / 400 V) 60 °C 40 A | |
(220 / 230 / 240 V) 60 °C 40 A | |
Rated Operational Power AC-3 (Pe): | (415 V) 22 kW |
(440 V) 22 kW | |
(500 V) 22 kW | |
(690 V) 22 kW | |
(380 / 400 V) 18.5 kW | |
(220 / 230 / 240 V) 11 kW | |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A | |
for 1 s -empty- A | |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A | |
Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 24 ... 60 V |
50 Hz / 60 Hz 24 ... 60 V | |
60 Hz 24 ... 60 V | |
DC Operation 20 ... 60 V | |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 4 ... 35 mm² |
Rigid 1/2x 6 ... 3 5 mm² | |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Rigid 1/2x 1 ... 2.5 mm² | |
Wire Stripping Length: | Main Circuit 16 mm |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
Terminal Type: | Screw Terminals |
Technical UL/CSA | |
General Use Rating UL/CSA: | (600 V AC) 60 A |
Horsepower Rating UL/CSA: | (120 V AC) Single Phase 3 hp |
(200 ... 208 V AC) Three Phase 10 hp | |
(220 ... 240 V AC) Three Phase 15 hp | |
(240 V AC) Single Phase 7-1/2 hp | |
(440 ... 480 V AC) Three Phase 30 hp | |
(550 ... 600 V AC) Three Phase 40 hp | |
| |
Ambient Air Temperature: | Close to Contactor for Storage -60 ... +80 °C |
Near Contactor for Operation in Free Air -40 ... +70 °C | |
Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5 ... 300 Hz 3 g Closed position / 2 g Open position |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
BV Certificate: | BV_2634H36994A |
CB Certificate: | CB_SE-96554M2 |
CCC Certificate: | CCC_2015010304824714 |
CQC Certificate: | CQC2015010304824714 |
Declaration of Conformity - CCC: | 2020980304001256 |
Declaration of Conformity - CE: | 1SBD250001U1000 |
DNV Certificate: | DNV-GL_TAE00001AF-3 |
DNV GL Certificate: | DNV-GL_TAE00001AF-3 |
EAC Certificate: | EAC_RU_FRME77B03447 |
GL Certificate: | DNV-GL_TAE00001AF-3 |
Instructions and Manuals: | 1SBC101047M6801 |
KC Certificate: | KC_HW02016-15009C |
RoHS Information: | 1SBD250001U1000 |
UL Certificate: | UL_20141124-E312527-14-2 |
UL Listing Card: | UL_E312527 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 150 mm |
Package Level 1 Depth / Length: | 150 mm |
Package Level 1 Height: | 103 mm |
Package Level 1 Gross Weight: | 1.32 kg |
Package Level 1 EAN: | 3471523133815 |
Package Level 2 Units: | box 8 piece |
Package Level 2 Width: | 250 mm |
Package Level 2 Depth / Length: | 300 mm |
Package Level 2 Height: | 300 mm |
Package Level 2 Gross Weight: | 10.56 kg |
Package Level 3 Units: | 192 piece |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121529 |
E-Number (Finland): | 3707553 |
E-Number (Sweden): | 3210300 |