Артикул: AF38ZB-40-00-21
Артикул: AF38ZB-40-00-21
AF38ZB-40-00-21 24-60V50/60HZ 20-60VDC Contactor
Мы подберем для вас подходящий продукт
Срочная доставка
Параллельный импорт
Конфигурация
General Information | |
Extended Product Type: | AF38ZB-40-00-21 |
Product ID: | 1SBL296261R2100 |
EAN: | 3471523124714 |
Catalog Description: | AF38ZB-40-00-21 24-60V50/60HZ 20-60VDC Contactor |
Long Description: | The AF38ZB-40-00-21 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 11 kW / 400 V AC (AC-3) and switching power circuits up to 55 A (AC-1) or 55 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Instructions and Manuals: | 1SBC101037M6801 |
| |
Product Net Width: | 45 mm |
Product Net Depth / Length: | 101 mm |
Product Net Height: | 86 mm |
Product Net Weight: | 0.41 kg |
| |
Number of Main Contacts NO: | 4 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 0 |
Number of Auxiliary Contacts NC: | 0 |
Standards: | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
Rated Operational Voltage: | Main Circuit 690 V |
Rated Frequency (f): | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 55 A |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 55 |
(690 V) 60 °C 45 A | |
(690 V) 70 °C 37 | |
Rated Operational Current AC-3 (Ie): | (415 V) 60 °C 21.2 A |
(440 V) 60 °C 20 A | |
(500 V) 60 °C 17.6 A | |
(690 V) 60 °C 10.5 A | |
(380 / 400 V) 60 °C 22 A | |
(220 / 230 / 240 V) 60 °C 23.2 A | |
Rated Operational Power AC-3 (Pe): | (400 V) 11 kW |
(415 V) 11 kW | |
(440 V) 11 kW | |
(500 V) 11 kW | |
(690 V) 9 kW | |
(220 / 230 / 240 V) 5.5 kW | |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | |
for 1 s -empty- A | |
Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 24 ... 60 V |
60 Hz 24 ... 60 V | |
DC Operation 20 ... 60 V | |
Operate Time: | Between Coil De-energization and NC Contact Closing 13 ... 98 ms |
Between Coil De-energization and NO Contact Opening 11 ... 95 ms | |
Between Coil Energization and NC Contact Opening 38 ... 90 ms | |
Between Coil Energization and NO Contact Closing 40 ... 95 ms | |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 1.5 ... 16 mm² |
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm² | |
Flexible with Insulated Ferrule 2x 1.5 ... 16 mm² | |
Rigid 1/2x 1.5 ... 16 mm² | |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Rigid 1/2x 1 ... 2.5 mm² | |
Wire Stripping Length: | Control Circuit 10 mm |
Main Circuit 12 mm | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 | |
Terminal Type: | Screw Terminals |
Technical UL/CSA | |
General Use Rating UL/CSA: | (600 V AC) 55 A |
| |
Ambient Air Temperature: | Close to Contactor for Storage -60 ... +80 °C |
Near Contactor for Operation in Free Air -40 ... +70 °C | |
Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible: | 3000 m |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CB Certificate: | CB_SE-96553 |
CCC Certificate: | CCC_2010010304445623 |
CQC Certificate: | CQC2010010304445623 |
Declaration of Conformity - CCC: | 2020980304001254 |
Declaration of Conformity - CE: | 1SBD250001U1000 |
EAC Certificate: | EAC_RU C-FR ME77 B03597 |
Environmental Information: | 1SBD250167E1000 |
GOST Certificate: | GOST_POCCFR.ME77.B07175.pdf |
Instructions and Manuals: | 1SBC101037M6801 |
KC Certificate: | KC_HW02016-15002C |
RoHS Information: | 1SBD250001U1000 |
UL Certificate: | UL_20120918-E319322-3-1 |
UL Listing Card: | UL_E319322 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 87 mm |
Package Level 1 Depth / Length: | 103 mm |
Package Level 1 Height: | 47 mm |
Package Level 1 Gross Weight: | 0.41 kg |
Package Level 1 EAN: | 3471523124714 |
Package Level 2 Units: | box 18 piece |
Package Level 2 Width: | 250 mm |
Package Level 2 Depth / Length: | 300 mm |
Package Level 2 Height: | 315 mm |
Package Level 2 Gross Weight: | 14.76 kg |
Package Level 3 Units: | 864 piece |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121529 |