Артикул: AF95B-30-11RT-72

Артикул: AF95B-30-11RT-72

AF95B-30-11RT 20-60V DC Contactor
Мы подберем для вас подходящий продукт
sales@industry-analytics.ru
+7 (926) 540-72-98
Срочная доставка
Параллельный импорт

Конфигурация



















































General Information
Extended Product Type: AF95B-30-11RT-72
Product ID: 1SFL437062R7211
EAN: 7320500260135
Catalog Description: AF95B-30-11RT 20-60V DC Contactor
Long Description: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 20-60V, DC

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Data Sheet, Technical Information: 1SBC100192C0206
Instructions and Manuals: 5309660-60
Dimension Diagram: 1SFB535001G1005

Dimensions
Product Net Width: 102 mm
Product Net Depth / Length: 123.5 mm
Product Net Height: 148 mm
Product Net Weight: 1.9 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 1
Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage: Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 145
(690 V) 55 °C 135
(690 V) 70 °C 115
Rated Operational Current AC-3 (Ie): (415 V) 55 °C 96 A
(440 V) 55 °C 93 A
(500 V) 55 °C 80 A
(690 V) 55 °C 65 A
(1000 V) 55 °C 30 A
(380 / 400 V) 55 °C 96 A
(220 / 230 / 240 V) 55 °C 96
Rated Operational Power AC-3 (Pe): (415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(1000 V) 40 kW
(380 / 400 V) 45 kW
(220 / 230 / 240 V) 25 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 160 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie): (110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-3 (Ie): (110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-5 (Ie): (110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 10 million
Maximum Mechanical Switching Frequency: 300 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc): DC Operation 20 ... 60 V
Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A
Holding at Max. Rated Control Circuit Voltage DC 2 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Operate Time: Between Coil De-energization and NC Contact Closing 60 ... 130 ms
Between Coil De-energization and NO Contact Opening 55 ... 125 ms
Between Coil Energization and NC Contact Opening 27 ... 77 ms
Between Coil Energization and NO Contact Closing 30 ... 80 ms
Connecting Capacity Main Circuit: Bar 30 mm²
Flexible with Cable End 2 x 6 ... 35 mm²
Rigid 2 x 6 ... 65 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles: M8 hexagon socket screw with single connector
Terminal Type: Ring-Tongue Terminals
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V
General Use Rating UL/CSA: (600 V AC) 125 A
Horsepower Rating UL/CSA: (200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 30 hp
(440 ... 480 V AC) Three Phase 60 hp
(550 ... 600 V AC) Three Phase 75 hp

Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible: 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 K40
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
ABS Certificate: 15-LD1408622-PDA
BV Certificate: 13409/C0 BV
CB Certificate: SE-73661
CQC Certificate: CQC2002010304007860
Declaration of Conformity - CCC: 2020980304001857
Declaration of Conformity - CE: 2CMT2015-005436
EAC Certificate: 9AKK107046A8618
Environmental Information: 1SFC101006D0201
GL Certificate: GL_20260-04HH
Instructions and Manuals: 5309660-60
LR Certificate: LR_04-00015-E1
RINA Certificate: ELE060313XG/002
RMRS Certificate: RMRS_12-03683-315
RoHS Information: 2CMT2015-005436
TÜV Certificate: MHM-EST-7.70017788e

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 130 mm
Package Level 1 Depth / Length: 265 mm
Package Level 1 Height: 162 mm
Package Level 1 Gross Weight: 2.1 kg
Package Level 1 EAN: 7320500260135

Classifications
Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4755 >> Contactors