Артикул: AFC16-30-10-80
Артикул: AFC16-30-10-80
AFC16-30-10-80 220-230V50Hz 230-240V60Hz Contactor
Мы подберем для вас подходящий продукт
Срочная доставка
Параллельный импорт
Конфигурация
General Information | |
Extended Product Type: | AFC16-30-10-80 |
Product ID: | 1SBL171001R8010 |
EAN: | 3471523014459 |
Catalog Description: | AFC16-30-10-80 220-230V50Hz 230-240V60Hz Contactor |
Long Description: | The AFC16-30-10-80 is a 3 poles - 690 V IEC or 600V UL contactor with 1 N.O built-in auxiliary contact and screw terminals, controlling motors up to 7.5 kW / 400 V AC (AC-3) or 10 hp / 480 V AC UL and switching power circuits up to 30 A (AC-1) or 30 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 220 … 230 V AC 50 Hz / 230 … 240 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Instructions and Manuals: | 1SBC101059M6801 |
| |
Product Net Width: | 45 mm |
Product Net Depth / Length: | 77 mm |
Product Net Height: | 86 mm |
Product Net Weight: | 0.298 kg |
| |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 1 |
Number of Auxiliary Contacts NC: | 0 |
Standards: | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
Rated Operational Voltage: | Auxiliary Circuit 690 V |
Main Circuit 690 V | |
Rated Frequency (f): | Auxiliary Circuit 50 / 60 Hz |
Main Circuit 50 / 60 Hz | |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A |
acc. to IEC 60947-5-1, q = 40 °C 16 A | |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 30 |
(690 V) 60 °C 30 A | |
(690 V) 70 °C 26 | |
Rated Operational Current AC-3 (Ie): | (415 V) 60 °C 18 A |
(440 V) 60 °C 18 A | |
(500 V) 60 °C 15 A | |
(690 V) 60 °C 10.5 A | |
(380 / 400 V) 60 °C 18 A | |
(220 / 230 / 240 V) 60 °C 18 A | |
Rated Operational Power AC-3 (Pe): | (400 V) 7.5 kW |
(415 V) 9 kW | |
(440 V) 9 kW | |
(500 V) 9 kW | |
(690 V) 9 kW | |
(380 / 400 V) 7.5 kW | |
(220 / 230 / 240 V) 4 kW | |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(400 / 440 V) 3 A | |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | |
for 0.1 s 140 A | |
for 1 s 100 A | |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A | |
Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
(AC-15) 1200 cycles per hour | |
(AC-2 / AC-4) 300 cycles per hour | |
(AC-3) 1200 cycles per hour | |
(DC-13) 900 cycles per hour | |
Rated Operational Current DC-13 (Ie): | (24 V) 6 A / 144 W |
(48 V) 2.8 A / 134 W | |
(72 V) 1 A / 72 W | |
(110 V) 0.55 A / 60 W | |
(125 V) 0.55 A / 69 W | |
(220 V) 0.27 A / 60 W | |
(250 V) 0.27 A / 68 W | |
(400 V) 0.15 A / 60 W | |
(500 V) 0.13 A / 65 W | |
(600 V) 0.1 A / 60 W | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V | |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 220 ... 230 V |
60 Hz 230 ... 240 V | |
Operate Time: | Between Coil De-energization and NC Contact Closing 9 ... 20 ms |
Between Coil De-energization and NO Contact Opening 4 ... 18 ms | |
Between Coil Energization and NC Contact Opening 7 ... 21 ms | |
Between Coil Energization and NO Contact Closing 10 ... 26 ms | |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | |
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
Rigid 1/2x 1 ... 6 mm² | |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
Rigid 1/2x 1 ... 2.5 mm² | |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Rigid 1/2x 1 ... 2.5 mm² | |
Wire Stripping Length: | Auxiliary Circuit 10 mm |
Control Circuit 10 mm | |
Main Circuit 10 mm | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
Terminal Type: | Screw Terminals |
Technical UL/CSA | |
General Use Rating UL/CSA: | (600 V AC) 30 A |
Horsepower Rating UL/CSA: | (120 V AC) Single Phase 1-1/2 hp |
(200 ... 208 V AC) Three Phase 5 hp | |
(220 ... 240 V AC) Three Phase 5 hp | |
(240 V AC) Single Phase 3 hp | |
(440 ... 480 V AC) Three Phase 10 hp | |
(550 ... 600 V AC) Three Phase 15 hp | |
Tightening Torque UL/CSA: | Auxiliary Circuit 11 IA |
Control Circuit 11 IA | |
Main Circuit 13 IA | |
| |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C |
Close to Contactor without Thermal O/L Relay -40 ... +70 °C | |
Close to Contactor for Storage -60 ... +80 °C | |
Near Contactor for Operation in Free Air -40 ... +70 °C | |
Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5 ... 300 Hz 4 g closed position / 2 g open position |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: B1 25 K40 |
Open, Shock Direction: B1 5 K40 | |
Shock Direction: A 30 K40 | |
Shock Direction: B2 15 K40 | |
Shock Direction: C1 25 K40 | |
Shock Direction: C2 25 K40 | |
| |
CB Certificate: | CB_SE-96551M1 |
CQC Certificate: | CQC2010010304445624 |
Declaration of Conformity - CCC: | 2020980304001253 |
Declaration of Conformity - CE: | 1SBD250024U1000 |
Instructions and Manuals: | 1SBC101059M6801 |
RoHS Information: | 1SBD251089E1000 |
UL Certificate: | UL_20191021-E312527_7_1 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 87 mm |
Package Level 1 Depth / Length: | 79 mm |
Package Level 1 Height: | 47 mm |
Package Level 1 Gross Weight: | 0.298 kg |
Package Level 1 EAN: | 3471523014459 |
Package Level 3 Units: | 1296 piece |
| |
Object Classification Code: | Q |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121529 |