Extended Product Type: | AE50-30-00RT 220V DC |
Product ID: | 1SBL359010R8800 |
EAN: | 3471522244284 |
Catalog Description: | AE50-30-00RT 220V DC Contactor |
Long Description: | AE50 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The AE..RT contactors are the Ring Tongue terminal version of the AE... range. The AE... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with standard double-winding DC coils (with add-on factory-mounted lagging contact for insertion of the"holding" winding) - Accessories: a wide range of accessories is available. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC101018D0202 |
Instructions and Manuals: | FPTC407767P0002 |
| |
Product Net Width: | 82 mm |
Product Net Depth / Length: | 108 mm |
Product Net Height: | 110 mm |
Product Net Weight: | 1.2 kg |
| |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 0 |
Number of Auxiliary Contacts NC: | 0 |
Standards: | Devices complying with international standards IEC 947-1 / 947-4-1 and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) according to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1 |
Rated Operational Voltage: | Main Circuit 1000 V |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 100 A |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 100 |
(690 V) 55 °C 85 | |
(690 V) 70 °C 70 | |
Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 50 A |
(440 V) 55 °C 45 A | |
(500 V) 55 °C 45 A | |
(690 V) 55 °C 35 A | |
(1000 V) 55 °C 23 A | |
(380 / 400 V) 55 °C 50 A | |
(220 / 230 / 240 V) 55 °C 53 | |
Rated Operational Power AC-3 (Pe): | (415 V) 25 kW |
(440 V) 25 kW | |
(500 V) 30 kW | |
(690 V) 30 kW | |
(380 / 400 V) 22 kW | |
(220 / 230 / 240 V) 15 kW | |
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
Short-Circuit Protective Devices: | gG Type Fuses 100 A |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A | |
Maximum Electrical Switching Frequency: | (AC-1) 300 cycles per hour |
(AC-2 / AC-4) 150 cycles per hour | |
(AC-3) 300 cycles per hour | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Mechanical Durability: | 5 million |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | DC Operation 220 V |
Coil Consumption: | Average Holding Value, from Warm State 4 W |
Average Pull-in Value, from Cold State 200 W | |
Pull-in at Max. Rated Control Circuit Voltage DC 200 W | |
Operate Time: | Between Coil Energization and NC Contact Opening 10 ... 27 ms |
Between Coil Energization and NO Contact Closing 30 ... 30 ms | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
Terminal Type: | Ring-Tongue Terminals |
| |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C |
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C | |
Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C | |
Close to Contactor for Storage -60 ... +80 °C | |
Climatic Withstand: | acc. to IEC 68-2-30 and 68-2-11 - UTE C 63-100 specification II |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: B1 10 K40 |
Open, Shock Direction: B1 5 K40 | |
Shock Direction: A 20 K40 | |
Shock Direction: B2 15 K40 | |
Shock Direction: C1 20 K40 | |
Shock Direction: C2 20 K40 | |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CB Certificate: | CB_FR_701506-A1 |
CQC Certificate: | CQC2018010304129269 |
CSA Certificate: | CSA_1033838_LR056745 |
Declaration of Conformity - CCC: | 2020980304001621 |
Declaration of Conformity - CE: | 1SBD250806U1000 |
EAC Certificate: | EAC_RU C-FR ME77 B01010 |
Environmental Information: | 1SBD250017E1003 |
GOST Certificate: | GOST_POCCFRME77B07175 |
Instructions and Manuals: | FPTC407767P0002 |
LR Certificate: | LRS_9830011 |
RINA Certificate: | RINA_ELE1007977 |
RoHS Information: | 1SBD250806U1000 |
UL Certificate: | UL_071301E39231 |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 140 mm |
Package Level 1 Depth / Length: | 146 mm |
Package Level 1 Height: | 96 mm |
Package Level 1 Gross Weight: | 1.2 kg |
Package Level 1 EAN: | 3471522244284 |
Package Level 2 Units: | box 20 piece |
Package Level 2 Gross Weight: | 24 kg |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
eClass: | V11.0 : 27371018 |
UNSPSC: | 39121529 |