Артикул: AF300B-30-11RT-69

Артикул: AF300B-30-11RT-69

AF300B-30-11RT 48-130V 50/60Hz / DC Contactor
Мы подберем для вас подходящий продукт
sales@industry-analytics.ru
+7 (926) 540-72-98
Срочная доставка
Параллельный импорт

Конфигурация




















































General Information
Extended Product Type: AF300B-30-11RT-69
Product ID: 1SFL557062R6911
EAN: 7320500260197
Catalog Description: AF300B-30-11RT 48-130V 50/60Hz / DC Contactor
Long Description: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 48-130 V, AC/DC

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Replacement Product ID (NEW): 1SFL587062R1222
Popular Downloads
Data Sheet, Technical Information: 1SBC100192C0206
Instructions and Manuals: 1SFC380003-89
Dimension Diagram: 53540930-2

Dimensions
Product Net Width: 140 mm
Product Net Depth / Length: 180.5 mm
Product Net Height: 227 mm
Product Net Weight: 5.4 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 1
Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage: Main Circuit 690 V
Rated Frequency (f): Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 500 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 500
(690 V) 55 °C 400
(690 V) 70 °C 325
Rated Operational Current AC-3 (Ie): (415 V) 55 °C 300 A
(440 V) 55 °C 280 A
(500 V) 55 °C 280 A
(690 V) 55 °C 280 A
(380 / 400 V) 55 °C 305 A
(220 / 230 / 240 V) 55 °C 305
Rated Operational Power AC-3 (Pe): (415 V) 160 kW
(440 V) 160 kW
(500 V) 200 kW
(690 V) 250 kW
(380 / 400 V) 160 kW
(220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 500 A
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie): (110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie): (110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie): (110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 5 million
Maximum Mechanical Switching Frequency: 300 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc): 50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A
Holding at Max. Rated Control Circuit Voltage DC 2 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Operate Time: Between Coil De-energization and NC Contact Closing 40 ... 50 ms
Between Coil De-energization and NO Contact Opening 43 ... 53 ms
Between Coil Energization and NC Contact Opening 45 ... 85 ms
Between Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main Circuit: Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles: Flat type c/w screws and bolts
Terminal Type: Ring-Tongue Terminals
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V
General Use Rating UL/CSA: (600 V AC) 400 A
Horsepower Rating UL/CSA: (200 V AC) Three Phase 100 hp
(208 V AC) Three Phase 100 hp
(220 ... 240 V AC) Three Phase 100 hp
(440 ... 480 V AC) Three Phase 250 hp
(550 ... 600 V AC) Three Phase 300 hp

Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Close to Contactor for Storage -40 ... +70 °C
Maximum Operating Altitude Permissible: 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 K40
Shock Direction: B1 5 K40
Shock Direction: B2 5 K40
Shock Direction: C1 5 K40
Shock Direction: C2 5 K40
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
ABS Certificate: 15-LD1408622-PDA
BV Certificate: 13409/C0 BV
CB Certificate: SE-69480
CQC Certificate: CQC2007010304256681
Declaration of Conformity - CCC: 2020980304001554
Declaration of Conformity - CE: 2CMT2015-005436
EAC Certificate: 9AKK107046A8618
Environmental Information: 1SFC101008D0201
GL Certificate: GL_20262-04HH
Instructions and Manuals: 1SFC380003-89
LOVAG Certificate: SE-0115200
LR Certificate: LR_04-00015-E1
RINA Certificate: ELE060313XG/002
RMRS Certificate: RMRS_12-03683-315
RoHS Information: 2CMT2015-005436

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 203 mm
Package Level 1 Depth / Length: 245 mm
Package Level 1 Height: 188 mm
Package Level 1 Gross Weight: 6.1 kg
Package Level 1 EAN: 7320500260197

Classifications
Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4755 >> Contactors