Артикул: AF16Z-30-01-21

Артикул: AF16Z-30-01-21

AF16Z-30-01-21 24-60V50/60HZ 20-60VDC Contactor
ΠœΡ‹ ΠΏΠΎΠ΄Π±Π΅Ρ€Π΅ΠΌ для вас подходящий ΠΏΡ€ΠΎΠ΄ΡƒΠΊΡ‚
sales@industry-analytics.ru
+7 (926) 540-72-98
Брочная доставка
ΠŸΠ°Ρ€Π°Π»Π»Π΅Π»ΡŒΠ½Ρ‹ΠΉ ΠΈΠΌΠΏΠΎΡ€Ρ‚

ΠšΠΎΠ½Ρ„ΠΈΠ³ΡƒΡ€Π°Ρ†ΠΈΡ














































































General Information
Extended Product Type: AF16Z-30-01-21
Product ID: 1SBL176001R2101
EAN: 3471523113916
Catalog Description: AF16Z-30-01-21 24-60V50/60HZ 20-60VDC Contactor
Long Description: The AF16Z-30-01-21 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 7.5 kW / 400 V AC (AC-3) or 10 hp / 480 V UL and switching power circuits up to 30 A (AC-1) or 30 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Instructions and Manuals: 1SBC101027M6801

Dimensions
Product Net Width: 45 mm
Product Net Depth / Length: 77 mm
Product Net Height: 86 mm
Product Net Weight: 0.31 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 1
Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 NΒ°14
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 Β°C 35 A
acc. to IEC 60947-5-1, q = 40 Β°C 16 A
Rated Operational Current AC-1 (Ie): (690 V) 40 Β°C 30
(690 V) 60 Β°C 30 A
(690 V) 70 Β°C 26
Rated Operational Current AC-3 (Ie): (415 V) 60 Β°C 18 A
(440 V) 60 Β°C 18 A
(500 V) 60 Β°C 15 A
(690 V) 60 Β°C 10.5 A
(380 / 400 V) 60 Β°C 18 A
(220 / 230 / 240 V) 60 Β°C 18 A
Rated Operational Power AC-3 (Pe): (400 V) 7.5 kW
(415 V) 9 kW
(440 V) 9 kW
(500 V) 9 kW
(690 V) 9 kW
(380 / 400 V) 7.5 kW
(220 / 230 / 240 V) 4 kW
Rated Operational Current AC-15 (Ie): (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Short-time Withstand Current (Icw): at 40 Β°C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
at 40 Β°C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
at 40 Β°C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 Β°C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 Β°C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie): (24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 24 ... 60 V
50 Hz / 60 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Operate Time: Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 ... 6 mmΒ²
Flexible with Insulated Ferrule 1x 0.75 ... 4 mmΒ²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mmΒ²
Rigid 1/2x 1 ... 6 mmΒ²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mmΒ²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mmΒ²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mmΒ²
Rigid 1/2x 1 ... 2.5 mmΒ²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mmΒ²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mmΒ²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mmΒ²
Rigid 1/2x 1 ... 2.5 mmΒ²
Wire Stripping Length: Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 10 mm
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type: Screw Terminals
Technical UL/CSA
General Use Rating UL/CSA: (600 V AC) 30 A
Horsepower Rating UL/CSA: (120 V AC) Single Phase 1-1/2 hp
(200 ... 208 V AC) Three Phase 5 hp
(220 ... 240 V AC) Three Phase 5 hp
(240 V AC) Single Phase 3 hp
(440 ... 480 V AC) Three Phase 10 hp
(550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA: Auxiliary Circuit 11 IA
Control Circuit 11 IA
Main Circuit 13 IA

Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 Β°C
Close to Contactor without Thermal O/L Relay -40 ... +70 Β°C
Close to Contactor for Storage -60 ... +80 Β°C
Near Contactor for Operation in Free Air -40 ... +70 Β°C
Climatic Withstand: Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible: 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 4 g closed position / 2 g open position
Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 25 K40
Open, Shock Direction: B1 5 K40
Shock Direction: A 30 K40
Shock Direction: B2 15 K40
Shock Direction: C1 25 K40
Shock Direction: C2 25 K40
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
ABS Certificate: ABS_15-GE1349500-PDA_90682247
BV Certificate: BV_2634H24898B0
CB Certificate: CB_SE-96551M1
CCC Certificate: CCC_2010010304445624
CQC Certificate: CQC2010010304445624
CQC2020010304298240
cUL Certificate: UL_20180227_E312527_7_1
Declaration of Conformity - CCC: 2020980304001253
2020980304001082
Declaration of Conformity - CE: 1SBD250000U1000
DNV Certificate: DNV-GL_TAE00001AF-3
DNV GL Certificate: DNV-GL_TAE00001AF-3
EAC Certificate: EAC_RU_FRME77B03447
Environmental Information: 1SBD250147E1000
GL Certificate: DNV-GL_TAE00001AF-3
GOST Certificate: GOST_POCCFR.ME77.B07175.pdf
Instructions and Manuals: 1SBC101027M6801
KC Certificate: KC_HW02016-15005C
LR Certificate: LRS_1300087E1
RINA Certificate: RINA_ELE240318XG
RMRS Certificate: RMRS_1802705280
RoHS Information: 1SBD250000U1000
UL Certificate: UL_20140305-E312527_7_1
UL Listing Card: E312527

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 87 mm
Package Level 1 Depth / Length: 79 mm
Package Level 1 Height: 47 mm
Package Level 1 Gross Weight: 0.31 kg
Package Level 1 EAN: 3471523113916
Package Level 2 Units: box 27 piece
Package Level 2 Width: 250 mm
Package Level 2 Depth / Length: 300 mm
Package Level 2 Height: 315 mm
Package Level 2 Gross Weight: 8.37 kg
Package Level 3 Units: 1296 piece

Classifications
Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529
E-Number (Finland): 3706256
E-Number (Sweden): 3211369