General Information
Extended Product Type: AF750-30-00 100-250V 50/60Hz / 100-250V DC
Product ID: 1SFL637001R7000
EAN: 7320500381175
Catalog Description: AF750-30-00 100-250V 50/60Hz / 100-250V DC Contactor
Long Description: The AF750-30-00 100-250V 50/60Hz / 100-250V DC is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 400 kW / 400 V AC (AC-3) or 600 hp / 480 V UL and switching power circuits up to 1050 A (AC-1) or 900 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Instructions and Manuals: 1SFC380023-en

Dimensions
Product Net Width: 210 mm
Product Net Depth / Length: 242 mm
Product Net Height: 283 mm
Product Net Weight: 13.6 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 0
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie): (1000 V) 40 °C 1000 A
(1000 V) 55 °C 875 A
(1000 V) 70 °C 720 A
(690 V) 40 °C 1050
(690 V) 55 °C 875
(690 V) 70 °C 720
Rated Operational Current AC-3 (Ie): (415 V) 55 °C 750 A
(440 V) 55 °C 750 A
(500 V) 55 °C 750 A
(690 V) 55 °C 650 A
(1000 V) 55 °C 300 A
(380 / 400 V) 55 °C 750 A
(220 / 230 / 240 V) 55 °C 750
Rated Operational Power AC-3 (Pe): (415 V) 425 kW
(440 V) 450 kW
(500 V) 520 kW
(690 V) 600 kW
(1000 V) 400 kW
(380 / 400 V) 400 kW
(220 / 230 / 240 V) 220 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
Maximum Electrical Switching Frequency: 300 cycles per hour
Rated Operational Current DC-1 (Ie): (110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-3 (Ie): (110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-5 (Ie): (110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 3 million
Maximum Mechanical Switching Frequency: 300 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 100...250 V
60 Hz 100...250 V
DC Operation 100 ... 250 V
Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A
Terminal Type: Main Circuit: Bars
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 1000 V
General Use Rating UL/CSA: (1000 V AC) 900 A
(600 V AC) 900 A
Horsepower Rating UL/CSA: (200 V AC) Three Phase 250 hp
(208 V AC) Three Phase 250 hp
(220 ... 240 V AC) Three Phase 300 hp
(440 ... 480 V AC) Three Phase 600 hp
(550 ... 600 V AC) Three Phase 700 hp

Environmental
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Certificates and Declarations (Document Number)
ABS Certificate: 15-LD1408622-PDA
BV Certificate: BV_13409-C0BV
CB Certificate: SE-82863
CCS Certificate: GB14T00030
CQC Certificate: CQC2007010304256684
CQC2012010304540080
cUL Certificate: UL_20111101-E36588
Declaration of Conformity - CCC: 2020980304001301
2020980304001045
Declaration of Conformity - CE: 2CMT2019-005796
DNV GL Certificate: TAE00001W1
EAC Certificate: 9AKK107046A8618
Environmental Information: 1SAC200044H0006
Instructions and Manuals: 1SFC380023-en
LR Certificate: 16-20064
PRS Certificate: TE_2092_880423_16
RINA Certificate: ELE060313XG_002
RMRS Certificate: 9AKK107045A6978
RoHS Information: 2CMT2019-005796
UL Listing Card: UL_E36588

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 280 mm
Package Level 1 Depth / Length: 375 mm
Package Level 1 Height: 310 mm
Package Level 1 Gross Weight: 15 kg
Package Level 1 EAN: 7320500381175

Classifications
Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4755 >> Contactors