AF96-30-11-13 100-250V50/60HZ-DC Contactor
Мы подберем для вас подходящий продукт
Срочная доставка
Параллельный импорт
Конфигурация
General Information | |
Extended Product Type: | AF96-30-11-13 |
Product ID: | 1SBL407001R1311 |
EAN: | 3471523133334 |
Catalog Description: | AF96-30-11-13 100-250V50/60HZ-DC Contactor |
Long Description: | The AF96-30-11-13 is a 3 pole - 1000 V IEC or 600 UL contactor with pre-mounted auxiliary contacts and screw terminals, controlling motors up to 45 kW / 400 V AC (AC-3) or 60 hp / 480 V UL and switching power circuits up to 130 A (AC-1) or 115 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Instructions and Manuals: | 1SBC101036M6801 |
| |
Product Net Width: | 82 mm |
Product Net Depth / Length: | 116 mm |
Product Net Height: | 125.5 mm |
Product Net Weight: | 1.21 kg |
| |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 1 |
Number of Auxiliary Contacts NC: | 1 |
Rated Operational Voltage: | Auxiliary Circuit 690 V |
Main Circuit 1000 V | |
Rated Frequency (f): | Auxiliary Circuit 50 / 60 Hz |
Main Circuit 50 / 60 Hz | |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 130 A |
acc. to IEC 60947-5-1, q = 40 °C 16 A | |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 130 |
(690 V) 60 °C 105 A | |
(690 V) 70 °C 90 | |
Rated Operational Current AC-3 (Ie): | (415 V) 60 °C 105 A |
(440 V) 60 °C 105 A | |
(500 V) 60 °C 80 A | |
(690 V) 60 °C 57 A | |
(1000 V) 55 °C 30 A | |
(1000 V) 60 °C 30 A | |
(380 / 400 V) 60 °C 105 A | |
(220 / 230 / 240 V) 60 °C 105 A | |
Rated Operational Power AC-3 (Pe): | (400 V) 55 kW |
(415 V) 55 kW | |
(440 V) 55 kW | |
(500 V) 55 kW | |
(690 V) 55 kW | |
(1000 V) 40 kW | |
(380 / 400 V) 55 kW | |
(220 / 230 / 240 V) 30 kW | |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(400 / 440 V) 3 A | |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | |
for 0.1 s 140 A | |
for 1 s 100 A | |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A | |
Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
(AC-15) 1200 cycles per hour | |
(AC-2 / AC-4) 150 cycles per hour | |
(AC-3) 1200 cycles per hour | |
(DC-13) 900 cycles per hour | |
Rated Operational Current DC-13 (Ie): | (24 V) 6 A / 144 W |
(48 V) 2.8 A / 134 W | |
(72 V) 1 A / 72 W | |
(110 V) 0.55 A / 60 W | |
(125 V) 0.55 A / 69 W | |
(220 V) 0.27 A / 60 W | |
(250 V) 0.27 A / 68 W | |
(400 V) 0.15 A / 60 W | |
(500 V) 0.13 A / 65 W | |
(600 V) 0.1 A / 60 W | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 100 ... 250 V |
50 Hz / 60 Hz 100 ... 250 V | |
60 Hz 100 ... 250 V | |
DC Operation 100 ... 250 V | |
Operate Time: | Between Coil De-energization and NC Contact Closing 19 ... 105 ms |
Between Coil De-energization and NO Contact Opening 17 ... 100 ms | |
Between Coil Energization and NC Contact Opening 38 ... 95 ms | |
Between Coil Energization and NO Contact Closing 42 ... 100 ms | |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 6 ... 50 mm² |
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | |
Rigid 1x 6 ... 70 mm² | |
Rigid 2x 6 ... 50 mm² | |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
Rigid 1/2x 1 ... 2.5 mm² | |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Rigid 1/2x 1 ... 2.5 mm² | |
Wire Stripping Length: | Main Circuit 17 mm |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
Terminal Type: | Screw Terminals |
Technical UL/CSA | |
Horsepower Rating UL/CSA: | (120 V AC) Single Phase 7-1/2 hp |
(200 ... 208 V AC) Three Phase 30 hp | |
(200 V AC) Three Phase 30 hp | |
(208 V AC) Three Phase 30 hp | |
(220 ... 240 V AC) Three Phase 40 hp | |
(240 V AC) Single Phase 40 hp | |
(440 ... 480 V AC) Three Phase 75 hp | |
(550 ... 600 V AC) Three Phase 75 hp | |
Tightening Torque UL/CSA: | Auxiliary Circuit 11 IA |
Control Circuit 11 IA | |
Main Circuit 53 IA | |
| |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C |
Close to Contactor without Thermal O/L Relay -40 ... +70 °C | |
Close to Contactor for Storage -60 ... +80 °C | |
Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5 ... 300 Hz 3 g closed position / 3 g open position |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: A 25 K40 |
Closed, Shock Direction: B1 25 K40 | |
Closed, Shock Direction: B2 15 K40 | |
Closed, Shock Direction: C1 25 K40 | |
Closed, Shock Direction: C2 25 K40 | |
Open, Shock Direction: B1 5 K40 | |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
ABS Certificate: | ABS_15-GE1349500-PDA_90682247 |
BV Certificate: | BV_2634H36994A |
CB Certificate: | CB_SE-96557M2 |
CCC Certificate: | CCC_2013010304646569 |
CQC Certificate: | CQC2013010304646569 |
Declaration of Conformity - CCC: | 2020980304001255 |
Declaration of Conformity - CE: | 1SBD250000U1000 |
DNV Certificate: | DNV-GL_TAE00001AF-3 |
DNV GL Certificate: | DNV-GL_TAE00001AF-3 |
EAC Certificate: | EAC_RU_FRME77B03447 |
Environmental Information: | 1SBD250168E1000 |
GL Certificate: | DNV-GL_TAE00001AF-3 |
Instructions and Manuals: | 1SBC101036M6801 |
KC Certificate: | KC_HW02016-15011C |
LR Certificate: | LRS_1300087E1 |
RINA Certificate: | RINA_ELE084013XG |
RMRS Certificate: | RMRS_1802705280 |
RoHS Information: | 1SBD250000U1000 |
UL Certificate: | UL_20130926-E312527_14_1 |
UL Listing Card: | UL_E312527 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 150 mm |
Package Level 1 Depth / Length: | 150 mm |
Package Level 1 Height: | 103 mm |
Package Level 1 Gross Weight: | 1.33 kg |
Package Level 1 EAN: | 3471523133334 |
Package Level 2 Units: | box 8 piece |
Package Level 2 Width: | 250 mm |
Package Level 2 Depth / Length: | 300 mm |
Package Level 2 Height: | 300 mm |
Package Level 2 Gross Weight: | 10.64 kg |
Package Level 3 Units: | 192 piece |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121529 |
E-Number (Finland): | 3707142 |