General Information | |
Extended Product Type: | AF2850T-30-11 230-240V 50/60Hz / 230-240V DC |
Product ID: | 1SFL687001R9101 |
EAN: | 7320500515433 |
Catalog Description: | AF2850T-30-11 230-240V 50/60Hz / 230-240V DC Contactor |
Long Description: | The AF2850T-30-11 230-240V 50/60Hz / 230-240V DC is a 3 pole - 1000 V IEC or 1000 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, switching power circuits up to 2850 A (AC-1) or 2850 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (220-240 V 50/60 Hz), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100192C0206 |
Instructions and Manuals: | 1SFC101050M0201 |
| |
Product Net Width: | 438 mm |
Product Net Depth / Length: | 244 mm |
Product Net Height: | 422 mm |
Product Net Weight: | 43 kg |
| |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 2 |
Number of Auxiliary Contacts NC: | 2 |
Rated Operational Voltage: | Main Circuit 1000 V |
Rated Frequency (f): | Main Circuit 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 2850 A |
Rated Operational Current AC-1 (Ie): | (1000 V) 40 °C 2850 A |
(1000 V) 55 °C 2600 A | |
(1000 V) 70 °C 2300 A | |
(690 V) 40 °C 2850 | |
(690 V) 55 °C 2600 | |
(690 V) 70 °C 2300 | |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 10000 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 3000 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 5500 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 12000 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 7500 A | |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 8400 A |
Maximum Electrical Switching Frequency: | (AC-1) 15 cycles per hour |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
acc. to UL/CSA 1000 V | |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Mechanical Durability: | 0.3 million |
Maximum Mechanical Switching Frequency: | 60 cycles per hour |
Coil Operating Limits: | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 70 °C) |
Rated Control Circuit Voltage (Uc): | 50 Hz 230 ... 240 V |
60 Hz 230...240 V | |
DC Operation 230 ... 240 V | |
Coil Consumption: | Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A |
Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A | |
Holding at Max. Rated Control Circuit Voltage DC 20.5 W | |
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A | |
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2540 V·A | |
Pull-in at Max. Rated Control Circuit Voltage DC 2290 W | |
Operate Time: | Between Coil De-energization and NC Contact Closing 35 ... 55 ms |
Between Coil De-energization and NO Contact Opening 35 ... 55 ms | |
Between Coil Energization and NC Contact Opening 50 ... 80 ms | |
Between Coil Energization and NO Contact Closing 50 ... 80 ms | |
Connecting Capacity Main Circuit: | Bar 100 mm² |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
Flexible 2x0.75 ... 2.5 mm² | |
Solid 2 x 1 ... 4 mm² | |
Stranded 2 x 1 .... 4 mm² | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
Terminal Type: | Screw Terminals |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 1000 V |
General Use Rating UL/CSA: | (1000 V AC) 2850 A |
(600 V AC) 2850 A | |
| |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25...+50 °C |
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40...+70 °C | |
Close to Contactor for Storage -40 ... +70 °C | |
Maximum Operating Altitude Permissible: | 3000 m |
RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| |
CB Certificate: | SEMKO_SE70500M1 |
CQC Certificate: | CQC2013010304604054 |
cUL Certificate: | 9AKK107046A8617 |
Declaration of Conformity - CCC: | 2020980304001265 |
Declaration of Conformity - CE: | 2CMT2019-005796 |
EAC Certificate: | 9AKK107046A8618 |
Environmental Information: | 1SFC101014D0201 |
Instructions and Manuals: | 1SFC101050M0201 |
RoHS Information: | 2CMT2019-005796 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 555 mm |
Package Level 1 Depth / Length: | 365 mm |
Package Level 1 Height: | 500 mm |
Package Level 1 Gross Weight: | 45 kg |
Package Level 1 EAN: | 7320500515433 |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121529 |
IDEA Granular Category Code (IGCC): | 4755 >> Contactors |