A300-30-00 230-240V 50Hz Contactor
Мы подберем для вас подходящий продукт
sales@industry-analytics.ru
+7 (926) 540-72-98
Срочная доставка
Параллельный импорт

Конфигурация











































General Information
Extended Product Type: A300-30-00-42
Product ID: 1SFL551001R4200
EAN: 7320500217108
Catalog Description: A300-30-00 230-240V 50Hz Contactor
Long Description: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Replacement Product ID (NEW): 1SFL587002R1300
Popular Downloads
Data Sheet, Technical Information: 1SBC100192C0206
Instructions and Manuals: 1SFC380003-89
Dimension Diagram: 53540930-2

Dimensions
Product Net Width: 140 mm
Product Net Depth / Length: 180.5 mm
Product Net Height: 227 mm
Product Net Weight: 5.4 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 0
Rated Operational Voltage: Main Circuit 690 V
Rated Frequency (f): Main Circuit 50 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 500 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 500
(690 V) 55 °C 400
(690 V) 70 °C 325
Rated Operational Current AC-3 (Ie): (415 V) 55 °C 300 A
(440 V) 55 °C 280 A
(500 V) 55 °C 280 A
(690 V) 55 °C 280 A
(380 / 400 V) 55 °C 305 A
(220 / 230 / 240 V) 55 °C 305
Rated Operational Power AC-3 (Pe): (415 V) 160 kW
(440 V) 160 kW
(500 V) 200 kW
(690 V) 250 kW
(380 / 400 V) 160 kW
(220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 160 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie): (110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie): (110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie): (110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 5 million
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc): 50 Hz 230 ... 240 V
60 Hz 277 V
Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A
Operate Time: Between Coil De-energization and NC Contact Closing 7 ... 13 ms
Between Coil Energization and NO Contact Closing 17 ... 35 ms
Connecting Capacity Main Circuit: Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles: Flat type c/w screws and bolts
Terminal Type: Main Circuit: Bars
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V
General Use Rating UL/CSA: (600 V AC) 400 A
Horsepower Rating UL/CSA: (200 V AC) Three Phase 100 hp
(208 V AC) Three Phase 100 hp
(220 ... 240 V AC) Three Phase 100 hp
(440 ... 480 V AC) Three Phase 250 hp
(550 ... 600 V AC) Three Phase 300 hp

Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Close to Contactor for Storage -40 ... +70 °C
Maximum Operating Altitude Permissible: 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 K40
Shock Direction: B1 5 K40
Shock Direction: B2 5 K40
Shock Direction: C1 5 K40
Shock Direction: C2 5 K40
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
BV Certificate: 09826/C0 BV
CQC Certificate: CQC2008010304279325
CSA Certificate: 306708
Declaration of Conformity - CCC: 2020980304001552
Declaration of Conformity - CE: 2CMT2015-005436
DNV Certificate: DNV_E-12191
Environmental Information: 1SFC101003D0201
GL Certificate: GL_15529-00HH
Instructions and Manuals: 1SFC380003-89
LOVAG Certificate: SE9837128
LR Certificate: LR_12-70003
RINA Certificate: ELE060313XG/001
RMRS Certificate: RMRS_12-03683-315
RoHS Information: 2CMT2015-005436

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 203 mm
Package Level 1 Depth / Length: 245 mm
Package Level 1 Height: 188 mm
Package Level 1 Gross Weight: 6.1 kg
Package Level 1 EAN: 7320500217108

Classifications
Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4755 >> Contactors