Артикул: A26-30-01 220-230V 50Hz / 230-240V 60Hz
Артикул: A26-30-01 220-230V 50Hz / 230-240V 60Hz
A26-30-01 220-230V 50Hz / 230-240V 60Hz Contactor
Мы подберем для вас подходящий продукт
Срочная доставка
Параллельный импорт
Конфигурация
General Information | |
Extended Product Type: | A26-30-01 220-230V 50Hz / 230-240V 60Hz |
Product ID: | 1SBL241001R8001 |
EAN: | 3471522061805 |
Catalog Description: | A26-30-01 220-230V 50Hz / 230-240V 60Hz Contactor |
Long Description: | A26 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Replacement Product ID (NEW): | 1SBL231001R8000 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100122C0202_Ch02 |
Instructions and Manuals: | FPTC407722P0001 |
| |
Product Net Width: | 54 mm |
Product Net Depth / Length: | 93.6 mm |
Product Net Height: | 90 mm |
Product Net Weight: | 0.6 kg |
| |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 0 |
Number of Auxiliary Contacts NC: | 1 |
Rated Operational Voltage: | Main Circuit 690 V |
Rated Frequency (f): | Supply Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 45 A |
acc. to IEC 60947-5-1, q = 40 °C 16 A | |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 45 |
(690 V) 55 °C 40 | |
(690 V) 70 °C 32 | |
Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 26 A |
(440 V) 55 °C 26 A | |
(500 V) 55 °C 22 A | |
(690 V) 55 °C 17 A | |
(380 / 400 V) 55 °C 26 A | |
(220 / 230 / 240 V) 55 °C 26 | |
Rated Operational Power AC-3 (Pe): | (415 V) 11 kW |
(440 V) 15 kW | |
(500 V) 15 kW | |
(690 V) 15 kW | |
(380 / 400 V) 11 kW | |
(220 / 230 / 240 V) 6.5 kW | |
Rated Operational Power AC-6b (Pe): | (230 / 240 V) 40 °C, 50 / 60 Hz 11.5 kvar |
(230 / 240 V) 55 °C, 50 / 60 Hz 11.5 kvar | |
(230 / 240 V) 70 °C, 50 / 60 Hz 9 kvar | |
(400 / 415 V) 40 °C, 50 / 60 Hz 19 kvar | |
(400 / 415 V) 70 °C, 50 / 60 Hz 15 kvar | |
(400 / 415 V) 55 °C, 50 / 60 Hz 19 kvar | |
(440 V) 40 °C, 50 / 60 Hz 20 kvar | |
(440 V) 55 °C, 50 / 60 Hz 20 kvar | |
(440 V) 70 °C, 50 / 60 Hz 16.5 kvar | |
(500 / 550 V), 40 °C, 50 / 60 Hz 23 kvar | |
(500 / 550 V) 55 °C, 50 / 60 Hz 23 kvar | |
(500 / 550 V) 70 °C, 50 / 60 Hz 19 kvar | |
(690 V) 40 °C, 50 / 60 Hz 32 kvar | |
(690 V) 55 °C, 50 / 60 Hz 32 kvar | |
(690 V) 70 °C, 50 / 60 Hz 26 kvar | |
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(380 / 400 V) 3 A | |
Short-Circuit Protective Devices: | Auxiliary Circuit - gG Type Fuses 10 A |
gG Type Fuses 50 A | |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A | |
Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
(AC-2 / AC-4) 300 cycles per hour | |
(AC-3) 1200 cycles per hour | |
Rated Operational Current DC-13 (Ie): | (24 V) 6 / 144 A |
(48 V) 2.8 / 134 A | |
(72 V) 2 / 144 A | |
(125 V) 1.1 / 138 A | |
(250 V) 0.55 / 138 A | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Mechanical Durability: | 10 million |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 220 ... 230 V |
60 Hz 230 ... 240 V | |
Coil Consumption: | Average Holding Value 50 / 60 Hz 12 V·A |
Average Pull-in Value 50 Hz 125 V·A | |
Average Pull-in Value 60 Hz 120 V·A | |
Operate Time: | Between Coil De-energization and NC Contact Closing 7 ... 14 ms |
Between Coil De-energization and NO Contact Opening 4 ... 11 ms | |
Between Coil Energization and NC Contact Opening 6 ... 18 ms | |
Between Coil Energization and NO Contact Closing 8 ... 21 ms | |
Connecting Capacity Main Circuit: | Flexible with Cable End 0.75 ... 4 mm² |
Rigid Cable 1.5 ... 6 mm² | |
Connecting Capacity Auxiliary Circuit: | Flexible with Cable End 0.75 ... 2.5 mm² |
Rigid Cable 1 ... 4 mm² | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
Connecting Terminals (delivered in open position) Main Poles: | M 4 (+,-) pozidriv 2 screws with cable clamp |
Terminal Type: | Screw Terminals |
| |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C |
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C | |
Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C | |
Close to Contactor for Storage -60 ... +80 °C | |
Climatic Withstand: | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: B1 10 K40 |
Open, Shock Direction: B1 5 K40 | |
Shock Direction: A 20 K40 | |
Shock Direction: B2 15 K40 | |
Shock Direction: C1 20 K40 | |
Shock Direction: C2 20 K40 | |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
BV Certificate: | BV_2634H07559E0 |
CB Certificate: | CB_FR_602227A |
CCC Certificate: | CCC_2013010304615752 |
CCC_2004010309133982 | |
CQC Certificate: | CQC2013010304615752 |
CQC2004010309133982 | |
CSA Certificate: | CSA_1033838_LR056745 |
Declaration of Conformity - CCC: | 2020980304001609 |
2020980304001227 | |
Declaration of Conformity - CE: | 1SBD250801U1000 |
DNV Certificate: | DNV-GL_TAE00000TX |
DNV GL Certificate: | DNV-GL_TAE00000TX |
EAC Certificate: | EAC_RU C-FR ME77 B03599 |
Environmental Information: | 1SBD250004E1003 |
Instructions and Manuals: | FPTC407722P0001 |
LR Certificate: | LRS_9830011E4 |
RINA Certificate: | RINA_ELE172319XG001 |
RMRS Certificate: | RMRS_0507015250 |
RoHS Information: | 1SBD250801U1000 |
UL Certificate: | UL_071301E39231 |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 101 mm |
Package Level 1 Depth / Length: | 115 mm |
Package Level 1 Height: | 61 mm |
Package Level 1 Gross Weight: | 0.6 kg |
Package Level 1 EAN: | 3471522061805 |
Package Level 2 Units: | box 24 piece |
Package Level 2 Width: | 300 mm |
Package Level 2 Depth / Length: | 245 mm |
Package Level 2 Height: | 308 mm |
Package Level 2 Gross Weight: | 14.4 kg |
Package Level 3 Units: | 576 piece |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121529 |