A95-30-22 400-415V 50Hz / 480V 60Hz Contactor
Мы подберем для вас подходящий продукт
Срочная доставка
Параллельный импорт
Конфигурация
General Information | |
Extended Product Type: | A95-30-22-51 |
Product ID: | 1SFL431001R5122 |
EAN: | 7320500136218 |
Catalog Description: | A95-30-22 400-415V 50Hz / 480V 60Hz Contactor |
Long Description: | A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Replacement Product ID (NEW): | 1SBL407001R1422 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100192C0206 |
Instructions and Manuals: | 5309660-60 |
Dimension Diagram: | 53540923-1 |
| |
Product Net Width: | 90 mm |
Product Net Depth / Length: | 155.6 mm |
Product Net Height: | 170 mm |
Product Net Weight: | 1.8 kg |
| |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 2 |
Number of Auxiliary Contacts NC: | 2 |
Rated Operational Voltage: | Main Circuit 1000 V |
Rated Frequency (f): | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 145 |
(690 V) 55 °C 135 | |
(690 V) 70 °C 115 | |
Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 96 A |
(440 V) 55 °C 93 A | |
(500 V) 55 °C 80 A | |
(690 V) 55 °C 65 A | |
(1000 V) 55 °C 30 A | |
(380 / 400 V) 55 °C 96 A | |
(220 / 230 / 240 V) 55 °C 96 | |
Rated Operational Power AC-3 (Pe): | (415 V) 55 kW |
(440 V) 55 kW | |
(500 V) 55 kW | |
(690 V) 55 kW | |
(1000 V) 40 kW | |
(380 / 400 V) 45 kW | |
(220 / 230 / 240 V) 25 kW | |
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
Short-Circuit Protective Devices: | gG Type Fuses 160 A |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A | |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A | |
Maximum Electrical Switching Frequency: | (AC-1) 300 cycles per hour |
(AC-2 / AC-4) 150 cycles per hour | |
(AC-3) 300 cycles per hour | |
Rated Operational Current DC-1 (Ie): | (110 V) 2 Poles in Series, 40 °C 145 A |
(220 V) 3 Poles in Series, 40 °C 145 A | |
Rated Operational Current DC-3 (Ie): | (110 V) 2 Poles in Series, 40 °C 145 A |
(220 V) 3 Poles in Series, 40 °C 145 A | |
Rated Operational Current DC-5 (Ie): | (110 V) 2 Poles in Series, 40 °C 145 A |
(220 V) 3 Poles in Series, 40 °C 145 A | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 8 kV |
Mechanical Durability: | 10 million |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Coil Operating Limits: | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
Rated Control Circuit Voltage (Uc): | 50 Hz 400 ... 415 V |
60 Hz 480 V | |
Coil Consumption: | Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A |
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A | |
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | |
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A | |
Operate Time: | Between Coil De-energization and NC Contact Closing 7 ... 15 ms |
Between Coil De-energization and NO Contact Opening 10 ... 18 ms | |
Between Coil Energization and NC Contact Opening 7 ... 22 ms | |
Between Coil Energization and NO Contact Closing 10 ... 25 ms | |
Connecting Capacity Main Circuit: | Bar 30 mm² |
Flexible with Cable End 2 x 6 ... 35 mm² | |
Rigid 2 x 6 ... 65 mm² | |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
Flexible 2x0.75 ... 2.5 mm² | |
Solid 1 x 1 ... 4 mm² | |
Stranded 2 x 1 .... 4 mm² | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
Connecting Terminals (delivered in open position) Main Poles: | M8 hexagon socket screw with single connector |
Terminal Type: | Cable Clamp |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V |
General Use Rating UL/CSA: | (600 V AC) 125 A |
Horsepower Rating UL/CSA: | (200 V AC) Three Phase 30 hp |
(208 V AC) Three Phase 30 hp | |
(220 ... 240 V AC) Three Phase 30 hp | |
(440 ... 480 V AC) Three Phase 60 hp | |
(550 ... 600 V AC) Three Phase 75 hp | |
| |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C |
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C | |
Close to Contactor for Storage -60 ... +80 °C | |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Shock acc. to IEC 60068-2-27: | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 K40 |
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 K40 | |
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 K40 | |
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 K40 | |
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 K40 | |
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 K40 | |
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 K40 | |
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 K40 | |
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 K40 | |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
BV Certificate: | 07172/D0 BV |
CB Certificate: | SE-69430 |
CQC Certificate: | CQC2002010304008904 |
CQC2009010304353526 | |
Declaration of Conformity - CCC: | 2020980304001630 |
2020980304001078 | |
Declaration of Conformity - CE: | 2CMT2015-005436 |
DNV Certificate: | DNV_E-12191 |
Environmental Information: | 1SFC101001D0201 |
GL Certificate: | GL_99358-97HH |
Instructions and Manuals: | 5309660-60 |
LOVAG Certificate: | SE-9645071-1 |
LR Certificate: | LR_12-70027-E1 |
RINA Certificate: | ELE060313XG/001 |
RMRS Certificate: | RMRS_12-03683-315 |
RoHS Information: | 2CMT2015-005436 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 170 mm |
Package Level 1 Depth / Length: | 140 mm |
Package Level 1 Height: | 170 mm |
Package Level 1 Gross Weight: | 2 kg |
Package Level 1 EAN: | 7320500136218 |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121529 |
IDEA Granular Category Code (IGCC): | 4755 >> Contactors |