Артикул: AF40N2-30-11-11

Артикул: AF40N2-30-11-11

AF40N2-30-11-11 24-60V50/60HZ 20-60VDC Contactor
Мы подберем для вас подходящий продукт
sales@industry-analytics.ru
+7 (926) 540-72-98
Срочная доставка
Параллельный импорт

Конфигурация















































General Information
Extended Product Type: AF40N2-30-11-11
Product ID: 1SBL347001N1111
EAN: 3471523016637
Catalog Description: AF40N2-30-11-11 24-60V50/60HZ 20-60VDC Contactor
Long Description: The AF40N2-30-11-11 is a 3 pole - 600 V UL, NEMA size N2 contactor with pre-mounted auxiliary contacts and Screw, switching power circuits up to 60 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Technical
Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Product Name: Block Contactor
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Rated Control Circuit Voltage (Uc): 50 Hz 24 ... 60 V
50 Hz / 60 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Rated Operational Current AC-15 (Ie): (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Power Loss: at Rated Operating Conditions AC-1 per Pole 3 W
at Rated Operating Conditions AC-3 per Pole 1 W
Number of Main Contacts NC: 0
Number of Main Contacts NO: 3
Number of Auxiliary Contacts NC: 1
Number of Auxiliary Contacts NO: 1
Low Coil Consumption: No
Tightening Torque: Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Mounted Auxiliary Contacts: 1 NO, 1 NC
Mounting Position: Max. N.C. built-in and add-on N.C. auxiliary contacts: see accessory fitting details for a 3-pole contactor AF40 ... AF96
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid 1/2x 6 ... 3 5 mm²
Wire Stripping Length: Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 16 mm
Terminal Type: Screw Terminals

Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Close to Contactor for Storage -60 ... +80 °C
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Maximum Operating Altitude Permissible: 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 3 g closed position / 3 g open position
Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 25 K40
Closed, Shock Direction: B1 25 K40
Closed, Shock Direction: B2 15 K40
Closed, Shock Direction: C1 25 K40
Closed, Shock Direction: C2 25 K40
Open, Shock Direction: A 25 K40
Open, Shock Direction: B1 5 K40
Open, Shock Direction: B2 15 K40
Open, Shock Direction: C1 25 K40
Open, Shock Direction: C2 25 K40
RoHS Status: Following EU Directive 2011/65/EU
Technical UL/CSA
General Use Rating UL/CSA: (600 V AC) 60 A
Horsepower Rating UL/CSA: (120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 10 hp
(220 ... 240 V AC) Three Phase 15 hp
(240 V AC) Single Phase 7-1/2 hp
(440 ... 480 V AC) Three Phase 30 hp
(550 ... 600 V AC) Three Phase 40 hp
Tightening Torque UL/CSA: Auxiliary Circuit 11 IA
Control Circuit 11 IA
Main Circuit 35 IA

Dimensions
Product Net Width: 67 mm
Product Net Height: 125.5 mm
Product Net Depth / Length: 111 mm
Product Net Weight: 1.01 kg

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 150 mm
Package Level 1 Height: 97 mm
Package Level 1 Depth / Length: 150 mm
Package Level 1 Gross Weight: 1.11 kg
Package Level 1 EAN: 3471523016637
Package Level 3 Units: 240 piece

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Country of Origin: United States (US)
Selling Unit of Measure: piece

Certificates and Declarations (Document Number)
CB Certificate: CB_SE-96554M2
CQC Certificate: CQC2015010304824714
CQC2012010304589737
cUL Certificate: UL_20180227_E312527_7_1
Declaration of Conformity - CCC: 2020980304001256
2020980304001074
Declaration of Conformity - CE: 1SBD250027U1000
Instructions and Manuals: 1SBC101036M6801
RoHS Information: 1SBD250027U1000
UL Certificate: UL_20140305-E312527_7_1
UL Listing Card: UL_E312527
Popular Downloads
Instructions and Manuals: 1SBC101036M6801
Mounting Positions: 1SBC500297F0000
UL Listing Card: UL_E312527
EPLAN Graphical Macro: 9AKK106930A0715
EPLAN Macro: 9AKK106930A0714

Classifications
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
ETIM 8: EC000066 - Power contactor, AC switching
WEEE Category: Product Not in WEEE Scope
CN8: 8536 49 00
UNSPSC: 39121529
eClass: V11.0 : 27371003
Object Classification Code: Q