General Information
Extended Product Type: A110-30-22-59
Product ID: 1SFL451001R5922
EAN: 7320500227107
Catalog Description: A110-30-22 690V 60Hz Contactor
Long Description: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Data Sheet, Technical Information: 1SBC100192C0206
Instructions and Manuals: 5309660-60
Dimension Diagram: 53540923-1

Dimensions
Product Net Width: 90 mm
Product Net Depth / Length: 156.5 mm
Product Net Height: 148 mm
Product Net Weight: 1.8 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 2
Number of Auxiliary Contacts NC: 2
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 160
(690 V) 55 °C 145
(690 V) 70 °C 130
Rated Operational Current AC-3 (Ie): (415 V) 55 °C 110 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(1000 V) 55 °C 30 A
(380 / 400 V) 55 °C 110 A
(220 / 230 / 240 V) 55 °C 110
Rated Operational Power AC-3 (Pe): (415 V) 59 kW
(440 V) 59 kW
(500 V) 59 kW
(690 V) 75 kW
(1000 V) 40 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 160 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie): (110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie): (110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie): (110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 10 million
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc): 60 Hz 690 V
Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Operate Time: Between Coil De-energization and NC Contact Closing 7 ... 15 ms
Between Coil De-energization and NO Contact Opening 10 ... 18 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Between Coil Energization and NO Contact Closing 10 ... 25 ms
Connecting Capacity Main Circuit: Bar 30 mm²
Flexible with Cable End 2 x 6 ... 35 mm²
Rigid 2 x 6 ... 65 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles: M8 hexagon socket screw with single connector
Terminal Type: Cable Clamp
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V
General Use Rating UL/CSA: (600 V AC) 140 A
Horsepower Rating UL/CSA: (200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp

Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible: 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 K40
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
BV Certificate: 07172/D0 BV
CB Certificate: SE-69487
CQC Certificate: CQC2002010304008904
CQC2009010304353526
CSA Certificate: 314005
Declaration of Conformity - CCC: 2020980304001630
2020980304001078
Declaration of Conformity - CE: 2CMT2015-005436
DNV Certificate: DNV_E-12191
Environmental Information: 1SFC101001D0201
GL Certificate: GL_99358-97HH
Instructions and Manuals: 5309660-60
LOVAG Certificate: SE-9645071-2
LR Certificate: LR_12-70027-E1
RINA Certificate: ELE060313XG/001
RMRS Certificate: RMRS_12-03683-315
RoHS Information: 2CMT2015-005436

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 170 mm
Package Level 1 Depth / Length: 140 mm
Package Level 1 Height: 170 mm
Package Level 1 Gross Weight: 2 kg
Package Level 1 EAN: 7320500227107

Classifications
Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4755 >> Contactors